MSG-3100 HD Radio™ Vector Signal Generator
(Production Discontinuance) |
 |
|
 |


The MSG-3100 is a Vector Signal Generator specialized for production tests of HD Radio™ receiver.
Test Vector data needed for the tests has been stored into a built-in 1GB Flash Memory.
No Test Vector needs to be downloaded from external storage device to use the equipment. |
Refer to the certificate.
| ■ |
This equipment is suitable for production tests of HD Radio™ receiver. |
| ■ |
It is easily set by the accompanying operation software. |
| ■ |
Quick start-up is possible because of its non-O.S. design. |
| RF |
| Frequency Range |
100kHz to 170MHz |
| Frequency Step |
100Hz |
| Output Level |
-20dBµV to +126dBμV EMF |
| Out Step |
0.1dB |
| Accuracy |
±1dB |
| Frequency Flatness |
1MHz ≤ f±1dB,f < 1MHz±1.5dB |
| Distortion |
| •Harmonics |
< -30dB |
| •Non Harmonics |
< -50dB |
| Output Impedance |
50Ω |
| VSWR |
Typ. < 1.2 |
| Reference Frequency |
10MHz |
| Output Connector |
BNC |
| Range Out Signal |
Change Frequency : By setting |
| ・Output |
DC 5V Max. 50mA |
| ・Connector |
RCA Pin Jack |
|
| Orthogonal Modulation |
| I&Q Quantization bits |
16bit |
| I&Q Sampling Frequency |
2.97675MHz |
|
| DATA |
| Applicable Sampling Frequency |
| ・AM |
46.5117kHz |
| ・FM |
744.1875kHz |
| Test Vector Store Capacity |
1GB |
| Test Vector Record Length |
128MB |
|
| Interface |
| |
USB |
| |
RS-232C |
| |
GP-IB (Option) |
|
| General Data |
| Power requirements |
AC 90 to 240 V 50/60Hz, Approx.40VA |
| Dimensions |
240(W) x 100(H) x 350(D) mm |
| Weight |
Approx. 4kg |
| Operating Temperature Range |
0 to +40℃ |
| Guarantee Temperature Range |
10 to +35℃ |
|
| Caution on Use |
| This unit was certified by iBiquity Digital Corporation as a measuring instrument only for production. This unit was not certified to research, develop or troubles shoot HD Radio™ products. Meguro Electronics and iBiquity Digital take no responsibilities when this unit is used for other than the certified purpose. Please surely connect this unit with device-under-test with the prescribed cable. Due to the characteristics of the signal, transmitting signal to the air from this unit interferes with law and regulation related to radio wave.
|
|
| * |
HD Radio™ and the HD Radio logos are proprietary trademarks of iBiquity Digital Corp. |
| * |
Specifications are subject to change without notice. |
|
|  |