| MSG-2191 Infrared Radio Beacon Checker |
 |
|
 |


The MSG-2191 is a signal generator designed for generating simulation signal of VICS' Infrared Beacon and Radio-wave Beacon; it is used for testing Infrared/Radio-wave Beacon receivers. This unit is operated from a PC through USB interface by using the attached application software. Also, users can input their Infrared Beacon data and Radio-wave Beacon data to this unit from PC. A special designed antenna for transmitting/recovering beacon is attached as standard. Note: The application software is not capable of creating and editing data.
* In VICS (Vehicle Information and Communication System), Infrared Beacon (at Main trunk roads) and Radio-wave Beacon (at Expressways) are used for providing traffic congestion information to vehicles and collecting traveling time from vehicles. |
| ■ |
This unit has six Records for each Infrared data and Radio-wave data. Data from PC can be input into Record No. 1 to No. 5. (No. 0 is a fixed data for confirmation.) |
| ■ |
In case of the Radio-wave Beacon, the level can be set to be changed automatically to obtain such an image as a vehicle approaches to the Beacon and then, goes away. |
| ■ |
In case of the Infrared Beacon, down link and up link (two-way communication) tests can be performed. |
| ■ |
When turn power switch off, setting of this unit is saved by battery backup function. |
| ■ |
When turn power switch on, self-test function detects abnormity of this unit. |
 |
 |
[Operation screen] |
[Infrared/Radio-wave antenna unit] |
| Radio-wave beacon |
| Carrier frequency |
2.4997GHz (Fixed)
Frequency stability: Less than +/-1ppm |
| Output level |
-40 to -80dBm step 1dB
Level accuracy less than ±1dB
Output impedance 50Ω, VSWR less than 1.5 |
| Data modulation method |
GMSK 64kbps frequency deviation range ±16kHz |
| Positioning and direction |
AM modulation 1kHz (Square wave)10±2%
(Synchronizes to data clock 64kHz) |
| Recognition |
AM modulation signal phase inversion function |
| Record No. |
6 records
Record 0: Radio-wave Beacon data for confirmation
(Fixed data)
Record 1 to 5: Data can be input from PC (Max. 80 frames per record)
1 frame = {Header (19 byte) + Data (103 byte) are settable} |
| Antenna unit |
An Infrared/Radio-wave antenna unit is attached as standard |
|
| Infrared beacon |
| Modulation method |
Pulse amplitude modulation |
| Encoding form |
Manchester code |
| Communication rate |
Down 1024kbps Up 64kbps |
| Output level |
Electric signal output TTL level |
| Record No. |
6 records
Record 0: Infrared Beacon data for confirmation
(Fixed data)
Record 1 to 5: Data can be input from PC (Max. 80 frames per record)
1 frame = {Header (19 byte) + Data (103 byte) are settable} |
| Antenna unit |
An Infrared/Radio-wave antenna unit is attached as standard |
|
| General Data |
| USB interface |
USB2.0 |
| Cable type |
USB2.0 Standard A, B plug cable |
| Connector of MSG-2191 |
Standard B receptacle |
| Communication condition |
Communicates by virtual COM port driver |
| Power requirements |
AC90V to 240V 50/60Hz (Multi slot- in) 8.5VA |
| Dimensions, overall |
Approx. 240 (W)×70 (H)×240 (D) mm |
| Weight |
Approx. 1.5kg |
| Operating Temp. range |
+10ºC to +40ºC Less than 80%H (Non condensing) |
| Guarantee Temp. range |
Less than +10ºC to +35ºC 80%H (Non condensing) |
| Storage Temp. range |
Less than 0ºC to +50ºC 90%H (Non condensing) |
|
| * |