 |
|  |
 |
| MAK-6578A 2-Channel Automatic Distortion Meter |
 |
|
 |


The MAK-6578A is a remotely controllable automatic distortion meter that measures 400 or 1000Hz harmonic distortion and levels in the range 10Hz to 100kHz simultaneously on 2 channels.
Automatic frequency switching enables automatic frequency selection.
Also even for measurement of distortion of signal waveforms whose levels changes, full-scale calibration is not necessary, making the MAK-6578A ideal for applications requiring very high-speed measurement, such as production lines.
The MAK-6578A has a very-low 0.003% range among its distortion measurement ranges, enabling measurement of very-low distortion down to 0.001%.
Furthermore, back-up functions are provided so that the measuring conditions need not be set each time the power is switched on.
|
| ■ |
Low distortion can be measured (-100dB, 0.001%). |
| ■ |
Automatic frequency switching enables automatic frequency selection. |
| ■ |
2 channels are provided, enabling distortion (or level) measurements of 2 signals simultaneously. |
| ■ |
Correct distortion can be measured even if the measurement level changes. |
| ■ |
It is not necessary to set full scale levels. |
| ■ |
The MAK-6578A can also be used a high-sensitivity level meter. |
| ■ |
With back-up functions; Input and distortion ranges. |
| Distortion measurement section |
| Measurement frequency range |
| (1) |
400Hz for THD |
| (2) |
1000Hz for THD |
| Frequency tuning range |
Approx. ±7% with respect to the measurement fundamental |
| Measurement range |
0.001 to 30% in 9 ranges
0 to 0.003% (input level 1Vmin.)
0 to 0.01% (input level 0.3Vmin.)
0 to 0.03% (input level 0.1Vmin.)
0 to 0.1% (input level 0.03Vmin.)
0 to 0.3%, 0 to 1%, 0 to 3%, 0 to 10%, and 0 to 30% |
| Input level range |
3mVrms to 100Vrms, 9 ranges
0.003 to 0.01V, 0.01 to 0.03V, 0.03 to 0.1V, 0.1 to 0.3V, 0.3 to 1V, 1 to 3V, 3 to 10V, 10 to 30V, and 30 to 100V. |
| Input impedance |
Approx. 100kΩ, unbalanced |
| Input capacitance |
45pF max. |
| Automatic input control range |
Approx. 12dB |
| Accuracy |
±5% of maximum reading for all ranges.
±10% of max. Reading for 0.01%, 0.03%, and 0.1% ranges,and ±20% of max. Reading for 0.003% range. |
| Fundamental elimination |
THD band-elimination filter method |
| Fundamental elimination characteristics |
-80dB max. at ±3% Fo
-100dB max. at ±1% Fo |
| Output level |
Approx. 1VrmsAC at max.
Reading in each range |
| Output impedance |
Approx. 10kΩ |
|
| Level measurement section |
| Measurement frequency ranges |
20Hz to 50kHz ±0.5dB (1kHz reference) |
| 10Hz to 100kHz ±1dB (1kHz reference) |
| Measurement ranges |
9 ranges: 0.01 to 100Vrms f.s. in 1-3 sequence |
| Accuracy |
±3% of max. reading at 1kHz |
| Input impedance |
Approx. 100kΩ unbalanced |
| Input capacity |
45pF max. |
| Level at Output connector |
Approx. 1Vrms AC at max.
reading each range |
|
| General Data |
| Operating temperature range |
0℃ to 40℃ |
| Power requirements |
100, 115, 215, and 230 VAC ±10%, 50 / 60Hz |
| Dimensions & Weight |
Approx. 290(W)×160(H)×300(D), 7kg |
| Remote Control |
Remote control function provided |
|
| * |
Specifications are subject to change without notice. |
|
|  |